Mitsubishi MR‑E‑AG Error AL.93: Servo Amplifier Stop Alarm

Servo amplifier · taken from the manufacturer’s manual, pages cited

Alarm codeAL.93

Servo Amplifier Stop Alarm is triggered when the EMC and SC connection is open or there is a main circuit open. The manual's first action is: “After confirming safety, release the emergency stop.”

Model
Mitsubishi MR‑E‑AG
Display shows
Servo Amplifier Stop Alarm (AL.93)
Type
Alarm code
Source
Manual p. 82

What AL.93 means

Servo Amplifier Stop Alarm p. 82

Common causes

  • The connection between EMC and SC is open. p. 82
  • Main circuit open alarm. p. 82

What to do

  1. After confirming safety, release the emergency stop. p. 82
  2. Restore power to the main circuit. p. 82

Before you service the product, read the safety instructions in the manual p. 4.

If AL.93 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL.93; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.