Mitsubishi MR‑E‑AG Error AL.96: Original Setpoint Error Alarm

Servo amplifier · taken from the manufacturer’s manual, pages cited

Fault codeAL.96

Original Setpoint Error Alarm is triggered when the origin cannot be set, the setpoint exceeds the allowed range, or a command pulse is input after clearing an accumulated fault. The manual's first action is: “Identify and eliminate the cause of the accumulated fault.”

Model
Mitsubishi MR‑E‑AG
Display shows
Original Setpoint Error Alarm (AL.96)
Type
Fault code
Source
Manual p. 82

What AL.96 means

Original Setpoint Error Alarm p. 82

Common causes

  • Unable to set the origin. p. 82
  • Accumulated fault due to setpoint exceeding allowed range. p. 82
  • After clearing the accumulated fault, command pulse is input. p. 82
  • Please reset the travel origin. p. 82

What to do

  1. Identify and eliminate the cause of the accumulated fault. p. 82
  2. After clearing the accumulated fault, do not input that setpoint. p. 82
  3. Reduce the rotation speed. p. 82
  4. After clearing the accumulated fault, do not input that setpoint. p. 82

Before you service the product, read the safety instructions in the manual p. 4.

If AL.96 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL.96; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.