Fault codeAL 37

The Parameter Fault code indicates parameter values altered due to servo amplifier failure or selected an optional regenerative component that is not compatible with the servo amplifier used for parameter 0. The manual's first action is: “Replace the servo amplifier.”

Model
Mitsubishi MR‑E‑AG
Display shows
Parameter Fault (AL 37)
Type
Fault code
Source
Manual p. 79

What AL 37 means

Parameter Fault p. 79

Common causes

  • Parameter values altered due to servo amplifier failure. p. 79
  • Selected an optional regenerative component that is not compatible with the servo amplifier used for parameter 0. p. 79

What to do

  1. Replace the servo amplifier. p. 79
  2. Set parameter 0 correctly. p. 79

Before you service the product, read the safety instructions in the manual p. 4.

If AL 37 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL 37; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.