Overcurrent alarm occurs because the motor cannot follow due to insufficient tap time constant or excessive loop gains during synchronous tap control. The manual's first action is: “Readjust the tap time constant. Set a value double the value for the S command.”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Overcurrent alarm occurs (ALM32)
- Type
- Alarm code
- Source
- Manual p. 296
What ALM32 means
Overcurrent alarm occurs p. 296
Common causes
- The motor cannot follow because the tap time constant is too short. p. 296
- The speed loop gain is too high for synchronous tap control (Is there vibration when changing to synchronous control?) p. 296
- The current loop gain is too high during synchronous tap control. p. 296
- The closed loop and semi-closed loop settings for spindle control are incorrect. p. 296
- The gear ratio setting is incorrect. p. 296
What to do
- Readjust the tap time constant. Set a value double the value for the S command. p. 296
- Set 100% as the standard. p. 296
- Set SP219, SP220 setting value to too large. Set 100% as the standard. p. 296
- Check which detector's FB is being used. Spindle ENC = full closed loop: SP193/bit0=0 Motor PLG = semi-closed loop: SP193/bit0=1 p. 296
- Check the machine gear ratio. Number of gear teeth on spindle side : SP025 to SP028 Number of gear teeth on motor side : SP029 to SP032 p. 296
Before you service the product, read the safety instructions in the manual p. 4.
If ALM32 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about ALM32; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.