Error code13
Software processing error 1 because software process was not completed within specified time, version unchanged, or error repeats. The manual's first action is: “PR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Software processing error 1 (13)
- Type
- Error code
- Source
- Manual p. 309
What 13 means
Software processing error 1 p. 309
Common causes
- The software process was not completed within the specified time. (CPU1) p. 309
- The version was not changed. p. 309
- The error is always repeated. p. 309
- An abnormality was found in the ambient environment. p. 309
What to do
- PR p. 309
- Try replacing with the drive unit containing the original software version. p. 309
- Investigate item 2. p. 309
- Replace the drive unit. p. 309
- Take remedies according to the causes of the abnormality. Ex. High temperature: Check the cooling fan. Incomplete grounding: Additionally ground. p. 309
Before you service the product, read the safety instructions in the manual p. 4.
If 13 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 13; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.