Mitsubishi Electric MDS-C1 Series Error 13: Software processing error 1

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code13

Software processing error 1 because software process was not completed within specified time, version unchanged, or error repeats. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Software processing error 1 (13)
Type
Error code
Source
Manual p. 309

What 13 means

Software processing error 1 p. 309

Common causes

  • The software process was not completed within the specified time. (CPU1) p. 309
  • The version was not changed. p. 309
  • The error is always repeated. p. 309
  • An abnormality was found in the ambient environment. p. 309

What to do

  1. PR p. 309
  2. Try replacing with the drive unit containing the original software version. p. 309
  3. Investigate item 2. p. 309
  4. Replace the drive unit. p. 309
  5. Take remedies according to the causes of the abnormality. Ex. High temperature: Check the cooling fan. Incomplete grounding: Additionally ground. p. 309

Before you service the product, read the safety instructions in the manual p. 4.

If 13 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 13; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.