Mitsubishi Electric MDS-C1 Series Error 16: Magnetic pole position detection error

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code16

Magnetic pole position detection error because initial magnetic pole creation was incomplete or SP205 is set incorrectly. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Magnetic pole position detection error (16)
Type
Error code
Source
Manual p. 309

What 16 means

Magnetic pole position detection error p. 309

Common causes

  • Creation of the initial magnetic pole, required for motor control, was not completed. p. 309
  • SP205 = 0 p. 309
  • SP205 = 1 p. 309

What to do

  1. PR p. 309
  2. Carry out automatic adjustment of the PLG Z-phase. p. 309
  3. Set SP205 to 0, and turn the NC power ON again. Then, carry out automatic adjustment of the PLG Z-phase. p. 309

Before you service the product, read the safety instructions in the manual p. 4.

If 16 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 16; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.