Error code32
The power module's overcurrent protection activated, possibly indicating repeatability issues or drive unit failure before READY ON. The manual's first action is: “PR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- Power module overcurrent (32)
- Type
- Error code
- Source
- Manual p. 310
What 32 means
Power module overcurrent p. 310
Common causes
- The power module's overcurrent protection function activated. p. 310
- Check the repeatability. p. 310
- The alarm occurs before READY ON. (The drive unit is faulty.) p. 310
- Check the parameter setting. p. 310
- Motor type: SV025 Spindle: SP034, SP040, SP257 to SP384 p. 310
- The setting is large compared to the standard value. p. 310
- The standard value is set. p. 310
- Disconnect the UVW phase wiring from the terminal block, and the cannon plug from the motor. Check the insulation with a tester. p. 310
- There is no problem. p. 310
- Check the insulation between the motor power cable and FG. p. 310
- The motor is short-circuited. p. 310
- Check for any abnormalities in the motor's ambient environment. (Ex.: Ambient temperature, cutting water) p. 310
What to do
- PR p. 310
- Check investigation item 2 and following, and remove the cause of the fault. Then replace the drive unit. p. 310
- Investigate item 2. p. 310
- Correctly set. p. 310
- Investigate item 3. p. 310
- Set the standard value. p. 310
- Investigate item 4. p. 310
- Replace the motor's power cable. p. 310
- Investigate item 5. p. 310
- Replace the motor. (With the absolute position system, the zero point must be established.) p. 310
- Investigate item 7. p. 310
- Replace the drive unit. p. 310
Before you service the product, read the safety instructions in the manual p. 4.
If 32 is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 32; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.