Mitsubishi Electric MDS-C1 Series Error 32: Power module overcurrent

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code32

The power module's overcurrent protection activated, possibly indicating repeatability issues or drive unit failure before READY ON. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Power module overcurrent (32)
Type
Error code
Source
Manual p. 310

What 32 means

Power module overcurrent p. 310

Common causes

  • The power module's overcurrent protection function activated. p. 310
  • Check the repeatability. p. 310
  • The alarm occurs before READY ON. (The drive unit is faulty.) p. 310
  • Check the parameter setting. p. 310
  • Motor type: SV025 Spindle: SP034, SP040, SP257 to SP384 p. 310
  • The setting is large compared to the standard value. p. 310
  • The standard value is set. p. 310
  • Disconnect the UVW phase wiring from the terminal block, and the cannon plug from the motor. Check the insulation with a tester. p. 310
  • There is no problem. p. 310
  • Check the insulation between the motor power cable and FG. p. 310
  • The motor is short-circuited. p. 310
  • Check for any abnormalities in the motor's ambient environment. (Ex.: Ambient temperature, cutting water) p. 310

What to do

  1. PR p. 310
  2. Check investigation item 2 and following, and remove the cause of the fault. Then replace the drive unit. p. 310
  3. Investigate item 2. p. 310
  4. Correctly set. p. 310
  5. Investigate item 3. p. 310
  6. Set the standard value. p. 310
  7. Investigate item 4. p. 310
  8. Replace the motor's power cable. p. 310
  9. Investigate item 5. p. 310
  10. Replace the motor. (With the absolute position system, the zero point must be established.) p. 310
  11. Investigate item 7. p. 310
  12. Replace the drive unit. p. 310

Before you service the product, read the safety instructions in the manual p. 4.

If 32 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 32; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.