Overcurrent at Acceleration indicates overcurrent during acceleration when output current exceeds three times the VFD's rated current. The manual's first action is: “Check whether the U‑V‑W wiring to the motor has poor insulation; increase acceleration time; replace with a larger‑capacity AC motor drive.”
- Model
- Delta VFD110CT43F21A3
- Display shows
- Overcurrent at Acceleration (ocA)
- Type
- Error code
- Source
- Manual p. 297
What ocA means
Overcurrent at Acceleration p. 297
Common causes
- Overcurrent during acceleration; during acceleration, output current exceeds three times the VFD's rated current. p. 297
What to do
- Check whether the U‑V‑W wiring to the motor has poor insulation; increase acceleration time; replace with a larger‑capacity AC motor drive. p. 297