AL301 indicates a CANopen SYNC failed when the synchronous communication with the external controller has failed. The manual's first action is: “Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).”
- Model
- Delta ASDA-A2
- Display shows
- CANopen SYNC failed (AL301)
- Type
- Fault code
- Source
- Manual p. 56
What AL301 means
CANopen SYNC failed p. 56
Common causes
- The synchronous communication with the external controller has failed. p. 56
What to do
- Host send "Reset node" command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset). p. 56
- 6200-0301h p. 56
If AL301 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL301; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.