The motor collision error occurs when the motor collides with hardware equipment and the torque reaches the setting of P1-57 within the time set by P1-58. The manual's first action is: “1. Verify whether P1-57 is enabled. 2. Verify whether P1-57 is set too low and whether the P1-58 time is set too short.”
- Model
- Delta ASDA-A2 Series
- Display shows
- Motor Collision Error (AL030)
- Type
- Error code
- Source
- Manual p. 355
What AL030 means
Motor Collision Error p. 366
Common causes
- When the motor collides with hardware equipment, the torque reaches the setting of P1-57 within the time set by P1-58 p. 366
- Motor collision error p. 366
What to do
- 1. Verify whether P1-57 is enabled. 2. Verify whether P1-57 is set too low and whether the P1-58 time is set too short. p. 366
- 1. If it was mistakenly enabled, set P1-57 to 0. 2. Set the torque according to the actual required torque; setting it too low may cause false trips, setting it too high eliminates the protection function. p. 366
Before you service the product, read the safety instructions in the manual p. 3.
If AL030 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL030; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.