Delta ASDA-A2 Series Error AL011: Encoder Fault

Delta ASDA-A2 Series servo driver · taken from the manufacturer’s manual, pages cited

Fault codeAL011

The encoder fault occurs from encoder wiring error, encoder loose, or encoder poor wiring. The manual's first action is: “Verify that wiring follows the manual's recommended wiring diagram. Wire correctly.”

Model
Delta ASDA-A2 Series
Display shows
Encoder Fault (AL011)
Type
Fault code
Source
Manual p. 362

What AL011 means

Encoder Fault p. 362

Common causes

What to do

  1. Verify that wiring follows the manual's recommended wiring diagram. Wire correctly. p. 362
  2. Inspect the CN2 connector on the drive and the encoder connector; reinstall. p. 362
  3. Check whether the wiring between CN2 on the drive and the servo motor encoder ends is loose; reconnect the wiring. p. 362
  4. Motor fault – replace the motor p. 362

Before you service the product, read the safety instructions in the manual p. 3.

If AL011 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL011; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.