The regeneration error occurs when the regeneration resistor is not connected or too low, the regeneration switching transistor fails, or there is a parameter setting error. The manual's first action is: “Reconnect the regeneration resistor or recalculate its value”
- Model
- Delta ASDA-A2 Series
- Display shows
- Regeneration Error (AL005)
- Type
- Error code
- Source
- Manual p. 361
What AL005 means
Regeneration Error p. 361
Common causes
- Regeneration resistor not connected or too low p. 361
- Regeneration switching transistor failure p. 361
- Parameter setting error p. 361
What to do
- Reconnect the regeneration resistor or recalculate its value p. 361
- Return to dealer or manufacturer for service p. 361
- Reset the settings correctly p. 361
Before you service the product, read the safety instructions in the manual p. 3.
If AL005 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL005; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.