The position control error too large occurs when the maximum position error parameter is set too low, the gain is set too low, or the torque limit is set too low. The manual's first action is: “Verify the maximum position error parameter P2-35 (position control error warning condition) setting and increase the P2-35 value.”
- Model
- Delta ASDA-A2 Series
- Display shows
- Position Control Error Too Large (AL009)
- Type
- Error code
- Source
- Manual p. 362
What AL009 means
Position Control Error Too Large p. 362
Common causes
- Maximum position error parameter set too low p. 362
- Gain set too low p. 362
- Torque limit set too low p. 362
- External load too large p. 362
What to do
- Verify the maximum position error parameter P2-35 (position control error warning condition) setting and increase the P2-35 value. p. 362
- Confirm whether the setting is appropriate and adjust the gain correctly. p. 362
- Verify the torque limit value and adjust it correctly. p. 362
- Inspect external load; reduce the external load or re-evaluate motor capacity. p. 362
Before you service the product, read the safety instructions in the manual p. 3.
If AL009 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL009; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.
