The overload occurs from continuous use beyond the drive's rated load, improper control system parameter settings, or motor or encoder wiring error. The manual's first action is: “Increase motor capacity or reduce load”
- Model
- Delta ASDA-A2 Series
- Display shows
- Overload (AL006)
- Type
- Error code
- Source
- Manual p. 361
What AL006 means
Overload p. 361
Common causes
- Continuous use beyond the drive's rated load p. 361
- Improper control system parameter settings p. 361
- Motor or encoder wiring error p. 361
- Defective motor encoder p. 361
What to do
- Increase motor capacity or reduce load p. 361
- 1. Adjust control loop gain values. 2. Slow down acceleration/deceleration setting times. p. 361
- Correct the wiring p. 361
- Return to dealer or manufacturer for service p. 361
Before you service the product, read the safety instructions in the manual p. 3.
If AL006 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL006; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.