Delta ASDA-A2 Series Error AL026: Encoder internal data error

Delta ASDA-A2 Series servo driver · taken from the manufacturer’s manual, pages cited

Error codeAL026

Encoder internal data error indicates abnormal data in the encoder detected three times consecutively. The manual's first action is: “1. Verify that the motor grounding terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder wiring uses shielded cable.”

Model
Delta ASDA-A2 Series
Display shows
Encoder internal data error (AL026)
Type
Error code
Source
Manual p. 366

What AL026 means

Encoder internal data error p. 366

Common causes

  • Encoder error (internal data abnormal three consecutive times) p. 366

What to do

  1. 1. Verify that the motor grounding terminal is properly grounded. 2. Check whether the encoder signal wires are separated from power lines or high‑current circuits to avoid interference sources. 3. Ensure the encoder wiring uses shielded cable. p. 366
  2. 1. Please connect the grounding terminal (green) of the UVW connector to the driver’s heat‑dissipation part. 2. Please check that the encoder signal wires are properly separated from power lines or high‑current circuits. 3. Please use cable with shielding. 4. If the issue does not improve, return the unit to the dealer or original manufacturer for service. p. 366

Before you service the product, read the safety instructions in the manual p. 3.

If AL026 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL026; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.