Encoder initial magnetic field error indicates a misalignment in the UVW magnetic field position. The manual's first action is: “1. Verify that the motor grounding terminal is properly grounded. 2. Ensure the encoder signal wires are separated from power or high‑current lines to avoid interference. 3. Verify that the encoder cable uses shielding. If the issue persists, return to dealer or manufacturer for service.”
- Model
- Delta ASDA-A2 Series
- Display shows
- Encoder Initial Magnetic Field Error (AL024)
- Type
- Error code
- Source
- Manual p. 365
What AL024 means
Encoder Initial Magnetic Field Error p. 365
Common causes
- Encoder initial magnetic field error (UVW magnetic field position error) p. 365
What to do
- 1. Verify that the motor grounding terminal is properly grounded. 2. Ensure the encoder signal wires are separated from power or high‑current lines to avoid interference. 3. Verify that the encoder cable uses shielding. If the issue persists, return to dealer or manufacturer for service. p. 365
Before you service the product, read the safety instructions in the manual p. 3.
If AL024 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL024; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.