Delta ASDA-A2 Series Error ALO16: IGBT Overheat

Delta ASDA-A2 Series servo driver · taken from the manufacturer’s manual, pages cited

Error codeALO16

The IGBT overheat occurs from continuous use beyond the drive's rated load or drive output short circuit. The manual's first action is: “Check if the load is too large or motor current too high. Increase motor capacity or reduce load.”

Model
Delta ASDA-A2 Series
Display shows
IGBT Overheat (ALO16)
Type
Error code
Source
Manual p. 363

What ALO16 means

IGBT Overheat p. 363

Common causes

  • Continuous use beyond the drive's rated load p. 363
  • Drive output short circuit p. 363

What to do

  1. Check if the load is too large or motor current too high. Increase motor capacity or reduce load. p. 363
  2. Inspect drive output wiring and ensure correct wiring. p. 363

Before you service the product, read the safety instructions in the manual p. 3.

If ALO16 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ALO16; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.