Delta ASDA-A2 Series Error AL018: Detector Output Fault

Delta ASDA-A2 Series servo driver · taken from the manufacturer’s manual, pages cited

Error codeAL018

The detector output fault occurs from detector output fault caused by encoder error or output pulses exceed hardware allowable range. The manual's first action is: “Check error history (P4-00~P4-05) to confirm whether encoder errors (AL011, AL024, AL025, AL026) occurred.”

Model
Delta ASDA-A2 Series
Display shows
Detector Output Fault (AL018)
Type
Error code
Source
Manual p. 364

What AL018 means

Detector Output Fault p. 364

Common causes

  • Detector output fault caused by encoder error p. 364
  • Output pulses exceed hardware allowable range p. 364

What to do

  1. Check error history (P4-00~P4-05) to confirm whether encoder errors (AL011, AL024, AL025, AL026) occurred. p. 364
  2. Set parameters correctly: P1-76 > motor speed and motor speed * 60 * P1-46 * 4 < 19.8×10^6 p. 364

Before you service the product, read the safety instructions in the manual p. 3.

If AL018 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about AL018; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.