The detector output fault occurs from detector output fault caused by encoder error or output pulses exceed hardware allowable range. The manual's first action is: “Check error history (P4-00~P4-05) to confirm whether encoder errors (AL011, AL024, AL025, AL026) occurred.”
- Model
- Delta ASDA-A2 Series
- Display shows
- Detector Output Fault (AL018)
- Type
- Error code
- Source
- Manual p. 364
What AL018 means
Detector Output Fault p. 364
Common causes
- Detector output fault caused by encoder error p. 364
- Output pulses exceed hardware allowable range p. 364
What to do
- Check error history (P4-00~P4-05) to confirm whether encoder errors (AL011, AL024, AL025, AL026) occurred. p. 364
- Set parameters correctly: P1-76 > motor speed and motor speed * 60 * P1-46 * 4 < 19.8×10^6 p. 364
Before you service the product, read the safety instructions in the manual p. 3.
If AL018 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL018; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.