Encoder internal error indicates a fault in the encoder's internal memory or counting. The manual's first action is: “1. Verify that the motor grounding terminal is properly grounded. 2. Ensure the encoder signal wires are separated from power or high‑current lines to avoid interference. 3. Verify that the encoder cable uses shielding. 1. Connect the UVW connector grounding terminal (green) to the drive's heat‑sink. 2. Check that the encoder signal wires are properly isolated from power or high‑current lines. 3. Use a cable with shielding. 4. If the problem remains, return to dealer or manufacturer for service.”
- Model
- Delta ASDA-A2 Series
- Display shows
- Encoder Internal Error (AL025)
- Type
- Fault code
- Source
- Manual p. 365
What AL025 means
Encoder Internal Error p. 365
Common causes
- Encoder internal error (internal memory fault, internal counting fault) p. 365
What to do
- 1. Verify that the motor grounding terminal is properly grounded. 2. Ensure the encoder signal wires are separated from power or high‑current lines to avoid interference. 3. Verify that the encoder cable uses shielding. 1. Connect the UVW connector grounding terminal (green) to the drive's heat‑sink. 2. Check that the encoder signal wires are properly isolated from power or high‑current lines. 3. Use a cable with shielding. 4. If the problem remains, return to dealer or manufacturer for service. p. 365
Before you service the product, read the safety instructions in the manual p. 3.
If AL025 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about AL025; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.