Beijing-Fanuc 0i-MA Error 12

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code12

The motor output current is abnormally high, indicating motor insulation issues, incorrect spindle parameters, or a faulty SPM unit. The manual's first action is: “1) Inspect motor insulation condition. 2) Check spindle parameters. 3) Replace SPM unit.”

Model
Beijing-Fanuc 0i-MA
Display shows
12
Type
Error code
Source
Manual p. 740

What 12 means

Motor output current abnormally high. p. 740

Common causes

  • Motor output current abnormally high. p. 740
  • During execution of spindle sync command, another operating mode cannot be specified. Must cancel spindle sync before entering another mode. p. 740

What to do

  1. 1) Inspect motor insulation condition. 2) Check spindle parameters. 3) Replace SPM unit. p. 740
  2. Another operating mode (Cs control mode, positioning, etc.) was specified while executing spindle sync. p. 740

Before you service the product, read the safety instructions in the manual p. 18.

If 12 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 12; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.