The DC portion of PSM is overvoltage or incorrect PSM selection, indicating voltage exceeds system limits or improper mode switching. The manual's first action is: “1) Check the selected PSM2 and input power voltage; reduce motor power during deceleration. If voltage exceeds 253 V (200 V system) or 530 V (400 V system), increase power supply impedance.”
- Model
- Beijing-Fanuc 0i-MA
- Display shows
- 11
- Type
- Alarm code
- Source
- Manual p. 739
What 11 means
DC portion of PSM overvoltage (PSM alarm display: 7). Incorrect PSM selection (exceeds PSM maximum power). p. 739
Common causes
- DC portion of PSM overvoltage (PSM alarm display: 7). Incorrect PSM selection (exceeds PSM maximum power). p. 739
- When executing a servo mode command, other modes cannot be commanded; must cancel servo mode before entering another mode. p. 739
What to do
- 1) Check the selected PSM2 and input power voltage; reduce motor power during deceleration. If voltage exceeds 253 V (200 V system) or 530 V (400 V system), increase power supply impedance. p. 739
- In servo mode (rigid tapping, spindle positioning) another operation mode (Cs control, spindle sync, positioning) was commanded. p. 739
Before you service the product, read the safety instructions in the manual p. 18.
If 11 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.
This page summarises what the manufacturer’s manual says about 11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.