The PSM is ready but DC rectified voltage in SPM is too low, indicating a potential DC fuse blow or improper cable connection. The manual's first action is: “1) Replace the SPM unit. 2) Inspect motor insulation condition. 3) Replace the interface cable.”
- Model
- Beijing-Fanuc 0i-MA
- Display shows
- 03
- Type
- Fault code
- Source
- Manual p. 739
What 03 means
PSM is ready (indicated by 00), but DC rectified voltage in SPM is too low. DC fuse in SPM has blown (power component failure or motor grounding fault). JX1A/JX1B cable connection improper. p. 739
Common causes
- PSM is ready (indicated by 00), but DC rectified voltage in SPM is too low. DC fuse in SPM has blown (power component failure or motor grounding fault). JX1A/JX1B cable connection improper. p. 739
- Check the parameters of the Cs control detector (bit 5 of parameter No.4001 and bit 4 of parameter No.4018). p. 739
What to do
- 1) Replace the SPM unit. 2) Inspect motor insulation condition. 3) Replace the interface cable. p. 739
- When a high‑resolution magnetic pulse encoder (bit 5 of parameter No.4001 = 1) and Cs control function (bit 4 of parameter No.4018 = 1) are used but the parameters are not set, the spindle motor will not run. p. 739
Before you service the product, read the safety instructions in the manual p. 18.
If 03 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.
This page summarises what the manufacturer’s manual says about 03; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.
