Beijing-Fanuc 0i-MA Error 18

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code18

The SPM control circuit malfunction indicates abnormal program RAM data, indicating improper parameter settings or a faulty SPM control circuit board. The manual's first action is: “Replace the SPM control circuit board.”

Model
Beijing-Fanuc 0i-MA
Display shows
18
Type
Error code
Source
Manual p. 740

What 18 means

SPM control circuit malfunction (program RAM data is abnormal). p. 740

Common causes

  • SPM control circuit malfunction (program RAM data is abnormal). p. 740
  • Check bit 2 of parameter No.4001 and the PMC signal (ORCM). p. 740

What to do

  1. Replace the SPM control circuit board. p. 740
  2. Bit 2 of parameter No.4001 is set to 0 (position encoder signal not used), yet a positioning command using the position encoder (ORCMA) was entered. p. 740

Before you service the product, read the safety instructions in the manual p. 18.

If 18 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 18; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.