Beijing-Fanuc 0i-MA Error 19

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code19

The SPM circuit malfunction indicates abnormal initial value of phase U current detection circuit, indicating improper mode switching or a faulty SPM unit. The manual's first action is: “Replace the SPM unit.”

Model
Beijing-Fanuc 0i-MA
Display shows
19
Type
Error code
Source
Manual p. 740

What 19 means

SPM circuit malfunction (initial value of phase U current detection circuit is abnormal). p. 740

Common causes

  • SPM circuit malfunction (initial value of phase U current detection circuit is abnormal). p. 740
  • During execution of a positioning command, another operating mode cannot be specified; the positioning command must be cancelled before switching to another mode. p. 740

What to do

  1. Replace the SPM unit. p. 740
  2. When positioning with the magnetic sensor, another motion mode was commanded. p. 740

Before you service the product, read the safety instructions in the manual p. 18.

If 19 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 19; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.