Beijing-Fanuc 0i-MA Error 20

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code20

The SPM circuit malfunction indicates abnormal initial value of phase U current detection circuit, indicating improper parameter settings or a faulty SPM unit. The manual's first action is: “Replace the SPM unit.”

Model
Beijing-Fanuc 0i-MA
Display shows
20
Type
Error code
Source
Manual p. 740

What 20 means

SPM circuit malfunction (initial value of phase U current detection circuit is abnormal). p. 740

Common causes

  • SPM circuit malfunction (initial value of phase U current detection circuit is abnormal). p. 740
  • Check bit 5 of parameter No.4001, bit 5 of No.4014, and bit 4 of No.4018. p. 740

What to do

  1. Replace the SPM unit. p. 740
  2. The master‑slave motion function (parameter 4014 bit 5 = 1), high‑resolution magnetic encoder (parameter 4001 bit 5 = 1), and Cs contour control function (parameter 4081 bit 4 = 1) were all enabled simultaneously. These functions cannot be set together. p. 740

Before you service the product, read the safety instructions in the manual p. 18.

If 20 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 20; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.