The thermal relay inside the motor has tripped, indicating a problem with the motor's temperature or load conditions. The manual's first action is: “1) Inspect and correct the temperature and load conditions of peripheral devices. 2) If the fan motor does not run, replace it immediately.”
- Model
- Beijing-Fanuc 0i-MA
- Display shows
- 01
- Type
- Error code
- Source
- Manual p. 739
What 01 means
Thermal relay inside the motor has tripped. p. 739
Common causes
- Thermal relay inside the motor has tripped. p. 739
- Check the sequence of *ESP and MRDY (for MRDY, pay attention to the parameter setting for the MRDY signal – bit 0 of parameter No.4001). p. 739
What to do
- 1) Inspect and correct the temperature and load conditions of peripheral devices. 2) If the fan motor does not run, replace it immediately. p. 739
- Even though ESP (emergency stop signal; there are two signal types including PMC and PSM contact signals (2)) and MRDY (machine ready signal) are not input, SFR (forward rotation signal) / SRF (reverse rotation signal) / ORCM (direction command) are being input. p. 739
Before you service the product, read the safety instructions in the manual p. 18.
If 01 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.
This page summarises what the manufacturer’s manual says about 01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.