The SAFE TORQUE OFF code indicates the Safe Torque Off function is activated when the safety circuit signal connected to the XSTO connector is lost during start-up, operation, or when the inverter is stopped. The manual's first action is: “Check the safety circuit connections. For more information, refer to the appropriate inverter hardware manual and the Application Guide – Safe Torque Off for ACSM1, ACS850, and ACQ810 Inverters (3AFE68929814 [English]).”
- Model
- ABB ACS850
- Display shows
- SAFE TORQUE OFF (0xFF7A) (0031)
- Type
- Fault code
- Source
- Manual p. 293
What 0031 means
SAFE TORQUE OFF (0xFF7A) p. 293
Common causes
- Safe Torque Off function is activated, i.e., during start-up or operation, or when the inverter is stopped, the safety circuit signal connected to the XSTO connector is lost, and parameter 30.07 STO diagnostic is set to Fault. p. 293
What to do
- Check the safety circuit connections. For more information, refer to the appropriate inverter hardware manual and the Application Guide – Safe Torque Off for ACSM1, ACS850, and ACQ810 Inverters (3AFE68929814 [English]). p. 293
Before you service the product, read the safety instructions in the manual p. 179.
If 0031 is still not resolved