ABB ACS850 Error 0032: OVERSPEED (0x7310)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Error code0032

The OVERSPEED code indicates the motor speed exceeds the maximum allowed speed due to incorrect maximum/minimum speed settings, insufficient brake torque, or load changes while using torque setpoint. The manual's first action is: “Check the minimum/maximum speed settings, parameters 20.01 Maximum speed and 20.02 Minimum speed. Verify that the motor brake torque is sufficient. Check the torque control application. Determine whether a brake chopper and brake resistor are required.”

Model
ABB ACS850
Display shows
OVERSPEED (0x7310) (0032)
Type
Error code
Source
Manual p. 293

What 0032 means

OVERSPEED (0x7310) p. 293

Common causes

  • The motor speed exceeds the maximum allowed speed because the maximum/minimum speed settings are incorrect, the brake torque is too low, or the load changed while using torque setpoint. p. 293

What to do

  1. Check the minimum/maximum speed settings, parameters 20.01 Maximum speed and 20.02 Minimum speed. Verify that the motor brake torque is sufficient. Check the torque control application. Determine whether a brake chopper and brake resistor are required. p. 293

Before you service the product, read the safety instructions in the manual p. 179.

If 0032 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”

This page summarises what the manufacturer’s manual says about 0032; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.