ABB ACS850 Error 0024: INTBOARD OVERTEMP (0x7182)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Fault code0024

The INTBOARD OVERTEMP code indicates the interface board temperature between the power unit and control unit has exceeded the internal fault limit. The manual's first action is: “Allow the inverter to cool down. Check that the ambient temperature is not excessive. Verify that the cooling fan is operating. Ensure there is no obstruction to airflow. Check cabinet size and cooling performance.”

Model
ABB ACS850
Display shows
INTBOARD OVERTEMP (0x7182) (0024)
Type
Fault code
Source
Manual p. 292

What 0024 means

INTBOARD OVERTEMP (0x7182) p. 292

Common causes

  • Interface board (between power unit and control unit) temperature has exceeded the internal fault limit. p. 292

What to do

  1. Allow the inverter to cool down. Check that the ambient temperature is not excessive. Verify that the cooling fan is operating. Ensure there is no obstruction to airflow. Check cabinet size and cooling performance. p. 292

Before you service the product, read the safety instructions in the manual p. 179.

If 0024 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”