ABB ACS850 Error 0034: BRAKE NOT CLOSED (0x7186)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Fault code0034

The BRAKE NOT CLOSED code indicates a mechanical brake control fault activated when the brake confirmation does not reach the expected state during brake closing. The manual's first action is: “Check the mechanical brake wiring. Verify the mechanical brake settings in parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; check whether the brake is closed or open.”

Model
ABB ACS850
Display shows
BRAKE NOT CLOSED (0x7186) (0034)
Type
Fault code
Source
Manual p. 293

What 0034 means

BRAKE NOT CLOSED (0x7186) p. 293

Common causes

  • Mechanical brake control fault. The fault is activated if, during brake closing, the brake confirmation does not reach the expected state. p. 293

What to do

  1. Check the mechanical brake wiring. Verify the mechanical brake settings in parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; check whether the brake is closed or open. p. 293

Before you service the product, read the safety instructions in the manual p. 179.

If 0034 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”

This page summarises what the manufacturer’s manual says about 0034; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.