The BRAKE NOT OPEN code indicates a mechanical brake control fault activated when the brake confirmation does not reach the expected state during brake opening. The manual's first action is: “Check the mechanical brake wiring. Verify the mechanical brake settings in parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; check whether the brake is closed or open.”
- Model
- ABB ACS850
- Display shows
- BRAKE NOT OPEN (0x7187) (0035)
- Type
- Fault code
- Source
- Manual p. 293
What 0035 means
BRAKE NOT OPEN (0x7187) p. 293
Common causes
- Mechanical brake control fault. The fault is activated if, during brake opening, the brake confirmation does not reach the expected state. p. 293
What to do
- Check the mechanical brake wiring. Verify the mechanical brake settings in parameter group 42 Mech brake ctrl. Determine whether the issue is with the confirmation signal or the brake itself; check whether the brake is closed or open. p. 293
Before you service the product, read the safety instructions in the manual p. 179.
If 0035 is still not resolved
- 请联系当地的 ABB 代表 p. 296 “请联系当地的 ABB 代表”
This page summarises what the manufacturer’s manual says about 0035; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.