ABB ACS850 Error 0026: AUTOPHASICING (0x3187)

ABB ACS850 · taken from the manufacturer’s manual, pages cited

Error code0026

The AUTOPHASICING code indicates a routine step of automatic phase identification failed. The manual's first action is: “If possible, try a different automatic phase‑identification mode (see parameter 11.07 Autophasing mode).”

Model
ABB ACS850
Display shows
AUTOPHASICING (0x3187) (0026)
Type
Error code
Source
Manual p. 292

What 0026 means

AUTOPHASICING (0x3187) p. 292

Common causes

  • A routine step of automatic phase identification (see section “Automatic Phase Identification”, page 56) failed. p. 292

What to do

  1. If possible, try a different automatic phase‑identification mode (see parameter 11.07 Autophasing mode). p. 292

Before you service the product, read the safety instructions in the manual p. 179.

If 0026 is still not resolved

  • 请联系当地的 ABB 代表 p. 296
    “请联系当地的 ABB 代表”