ABB ACQ810 Error 0021: STO1 LOST (0x8182)

Pump control drive · taken from the manufacturer’s manual, pages cited

Fault code0021

STO1 LOST (0x8182) means safe torque off function is active, i.e. safety circuit signal 1 connected between XSTO:1 and XSTO:3 is lost. The manual's first action is: “Check safety circuit connections. For more information, see appropriate drive hardware manual, description of parameter 30.07 (page 196), and Application guide - Safe torque off function for ACSM1, ACS850 and ACQ810 drives (3AFE68929814 [English]).”

Model
ABB ACQ810
Display shows
STO1 LOST (0x8182) (0021)
Type
Fault code
Source
Manual p. 323

What 0021 means

STO1 LOST (0x8182) p. 323

Common causes

  • Safe torque off function is active, i.e. safety circuit signal 1 connected between XSTO:1 and XSTO:3 is lost. p. 323

What to do

  1. Check safety circuit connections. For more information, see appropriate drive hardware manual, description of parameter 30.07 (page 196), and Application guide - Safe torque off function for ACSM1, ACS850 and ACQ810 drives (3AFE68929814 [English]). p. 323

Before you service the product, read the safety instructions in the manual p. 195.

If 0021 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 0021; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.