This page provides manuals, user guides, handbooks, specifications, and maintenance instructions for Industrial. View online or download for free. Showing page 2582.
This Application Note describes a method for fast GC analysis of natural waxes from art and museum objects. The method is based on a short column (15 m x 0.32 mm x 0.1 µm) fitted with on-column injection to maximize sensitivity. For additional sensitivity, some analytical reagents can be used.
This document describes the usage method and experimental conditions of the Beta Blockers Application 2002 LC Column, as well as the compounds detected and their peak identification. The LC column used is Polaris 3µ C18-A with dimensions of 50 x 2.0mm. The eluent consists of A: H2O + 0.1% NH4OH, pH 10.0 (concentration of 25 mM) and B: MeCN, with a gradient ratio of A:B 65:35. The flow rate is 0.6 ml/min, detection is done at UV @ 215nm, and the temperature is set at 40°C.
This file is the datasheet of ASI CBSL60B, which introduces the features and characteristics of the product, including BVCBO, BVCEO, BVEBO, IC, VCBO, VCEO, VEBO, PDISS, TJ, TSTG, θθJC, etc.
This document demonstrates the benefits of using an evaporative light scattering detector (ELSD) coupled to the Agilent 971-FP Flash instrument for the analysis of a sample containing a mixture of UV and non-UV-active compounds. The ELSD can detect compounds without UV chromophores, preventing the loss of these compounds that would go undetected by UV and be discarded.
This article introduces a simple method for the determination of copper, zinc, iron, calcium, magnesium, sodium, and potassium in serum using flame atomic absorption spectroscopy. One milliliter of serum is diluted to 10 milliliters with deionized water, and the determination of seven elements is automatically performed.
This application note describes a method for the simultaneous ICP-OES analysis of multiple metals in fuel oils and lubricating oils using the Agilent Vista™ 7800 simultaneous ICP-OES. The application note provides detailed instructions for performing metal analysis on fuel oils and lubricating oils, including sample preparation, analysis procedures, calibration and result validation.
This document describes the features and characteristics of the BZX84C2V7–BZX84C51 series surface mount Zener diodes from Vishay Telefunken, including planar die construction, power dissipation, Zener voltage range, and suitability for automated assembly processes.
This document is the datasheet of ASI CBSL15. It introduces the features and characteristics of the product, including maximum ratings, test conditions, package dimensions, etc.
This document introduces the use of Agilent CE high sensitivity detection cell. Using this cell, ultra-low level impurity analysis of drug substances can be realized, and the impurity detection concentration can be as low as 0.1%