Agilent manuals, page 54
Agilent Pesticide Dynamic MRM Compound Database for Screening Identification Using the Agilent LC/MS Triple Quadrupole Systems Manual
This document introduces the dynamic MRM compound database for screening and identification of pesticides using Agilent Triple Quadrupole LC/MS systems
Agilent Protein Sizing Quantitation with the Agilent Protein 80 Protein 230 Kits on the Agilent 2100 Bioanalyzer Manual
The Agilent 2100 Bioanalyzer is used in protein analysis, which can measure protein fluorescence intensity by microfluidic capillary gel electrophoresis to determine protein molecular weight and concentration
Agilent Reliable Expression Profiling Using Low RNA Inputs Manual
The technique provides a method for performing gene expression analysis from a small amount of total RNA, including transcribing total RNA into cDNA, amplifying the cDNA by a linear amplification method to obtain sufficient amounts of Cy-labeled cRNA, and then performing microarray analysis on the Cy-labeled cRNA. The method requires only 10 nanograms of total RNA and takes less than 6.5 hours to complete.
Agilent High Throughput GC 2D-GC solutions using LTM Technology in combination with the Agilent 5975 MSD 7000 Triple Quadrupole MS Manual
This document presents solutions for high throughput GC and 2D-GC analysis using LTM technology in combination with the Agilent 5975 MSD and 7000 Triple Quadrupole MS. The LTM module offers fast GC analysis, independent column temperature control, and high heating rates.
Agilent Advances in capillary column backflushing Manual
This document introduces the features of the imported brand Capillary Flow Technology, including ease of use, ruggedness, inertness, usability to> 350 oC, excellent exclusion of air, no unpurged volumes, no porous materials into which compounds can dissolve ( peak tailing), fast thermal response, no outgassing or shedding of particles.
Agilent A Benchtop Sample Preparation Instrument_ New Solutions for GC GCMS Applications Manual
Agilent is announcing a new sample preparation instrument for GC, GC/MS, LC, and LC/MS applications. The instrument features dilution, internal standard addition, derivatization, and calibration curve standard preparation.
Agilent Ultra-Inert chemistry for Trace Level Analysis Manual
This document introduces a new ultra-inert GC column that has significantly improved sensitivity and accuracy for trace samples
Agilent Considerations for implementation optimization of capillary column backflush Manual
This document discusses the considerations for implementing and optimizing capillary column backflushing. It explains why capillary column backflushing should be implemented and lists the benefits of implementing it, including increased sample throughput, reduced costs, extended column life, and improved data quality.
Agilent M30_Detection of dioxins furans PCDDs PCDFs in marine sediments by triple quad GCMSMS instrument Manual
A method based on isotopic dilution with low resolution MRM acquisition for higher sensitivity was used for the determination of polychlorinated dibenzo-p-dioxins and dibenzofurans in sediments. The method is accurate and sensitive.
Agilent R04_Determination of trace levels of PAHs in food grade oils using heart-cutting 2D-GC triple quadrupole MS Manual
Determination of trace levels of PAHs in food grade oils using heart-cutting 2D-GC and triple quadrupole mass spectrometry
Agilent R15_ICP-MS The ultimate GC detector Manual
ICP-MS is a GC detector that provides universal, element-specific quantification. It offers rapid multi-element/isotope analysis and very high sensitivity.
Agilent B18_PAH analysis. GC columns selection best practices for success Manual
The document describes the optimal design for a mass spectrometer vacuum pump cover that reduces pump noise and facilitates oil changes. It also provides information on GC column selection and best practices for successful PAH analysis, as well as factors to consider in optimizing PAH analyses results.
Agilent C24_Evaluation of automated sample preparation retention time locked GC-MS automated data analysis for the metabolomic study of arabidopsis species Manual
This document describes a method for automated sample preparation, retention time locked GC-MS and automated data analysis for metabolomic study
Agilent C27_On-line sample preparation a quick easy way to improve lab productivity data quality Manual
The advantages of automating sample derivatization are presented, including increased productivity and reduced cost. Examples of sample derivatization with fatty acids, pentachlorophenol, and morphine are provided. Silylation derivatization of fatty acids improves peak shape and resolution.
Agilent Bond Elut Plexa Efficient Preparation of Phenols in Drinking Water Manual
Varian's Bond Elut Plexa solid phase extraction (SPE) column has a very high extraction capacity for analytes and efficient removal of contaminants, making it ideal for extraction of phenols from drinking water.