SY3000*-OMH0002 SY Series Electromagnetic Valve User Manual
This manual provides safety and design guidelines for the SY series electromagnetic valve, including warnings, cautions and hazard symbols. It explains the required air source, operating environment and the limits for pressure and temperature.
Installation, piping, wiring, lubrication and maintenance procedures are described in detail, together with troubleshooting steps and recommended corrective actions for common faults such as coil overheating or leakage. This manual is written in Chinese.
SMC SY3000 specifications
| Protection rating | IP65 |
|---|---|
| Operating voltage | AC200V / AC220V |
| Torque for M2 screw (SY3000) | 0.16 N·m |
| Torque for M3 screw (SY5000) | 0.8 N·m |
Source: SY3000*-OMH0002 SY Series Electromagnetic Valve User Manual
All SMC SY3000 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What safety symbols are used in the manual?
The manual uses three symbols: Caution (注意), Warning (警告) and Danger (危险).
From: SY3000*-OMH0002 SY Series Electromagnetic Valve User Manual
How should the installation torque be set for the valve screws?
Use the torque values specified for each model, e.g., 0.16 N·m for SY3000 M2 screws and 0.8 N·m for SY5000 M3 screws.
From: SY3000*-OMH0002 SY Series Electromagnetic Valve User Manual
What is the operating pressure range for the SY3000, SY5000 and SY7000 valves?
0.1~0.7 MPa.
From: SMC SY3000/5000/7000/9000 Series Solenoid Valve Product Data Sheet
What is the ambient and fluid temperature range?
-10 to 50 °C, with no freezing.
From: SMC SY3000/5000/7000/9000 Series Solenoid Valve Product Data Sheet