SMC AMS20/AMS30/AMS40/AMS60 Air Management System Operation Manual
The SMC AMS20, AMS30, AMS40 and AMS60 are Air Management Systems. This operation manual begins with safety instructions and model indication, then describes the names and functions of parts, mounting, piping, wiring, LED indication, initial configuration and AMS operation settings.
Later sections cover OPC UA, PROFINET, EtherNet/IP and EtherCAT configuration, function settings on the hub display, maintenance, troubleshooting and specifications. The manual states that the applicable fluid is dry air and gives an operating fluid temperature range of 0 to 50 °C.
SMC AMS20/AMS30/AMS40/AMS60 specifications
| Applicable fluid | Dry air |
|---|---|
| Operating fluid temperature range | 0 to 50 °C |
| Data rewrite limit | 1,500,000 times |
| External power supply requirement | UL1310 Class 2 power supply unit or UL61010-1 LIM |
| Recommended inlet air filtration | 5 μm or less |
Source: SMC AMS20/AMS30/AMS40/AMS60 Air Management System Operation Manual
All SMC AMS20/AMS30/AMS40/AMS60 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What fluid can be used with the Air Management System?
Dry air. The manual states that the applicable fluid for the product is dry air.
From: SMC AMS20/AMS30/AMS40/AMS60 Air Management System Operation Manual
What is the operating fluid temperature range?
The operating fluid temperature range is 0 to 50 °C.
From: SMC AMS20/AMS30/AMS40/AMS60 Air Management System Operation Manual
What is the intended use of the Air Management System?
It is intended to monitor, control, and display flow, pressure, and temperature information while connected to a communications protocol.
From: SMC AMS20/AMS30/AMS40/AMS60 Air Management System Instruction Manual
What equipment class is this product?
This product is class A equipment intended for use in an industrial environment.
From: SMC AMS20/AMS30/AMS40/AMS60 Air Management System Instruction Manual