Red CUB5 Manuals

ManualLib has 4 documents for the Red CUB5 (Other device): 1 datasheet, 3 user manuals. Every file can be read online or downloaded as a PDF for free.

Datasheet 1User Manual 3

Key facts

Brand
Red
Model
CUB5
Category
Other device
Documents
4
Languages
EN
Last added
2012-05-04

Start here

Red Lion CUB5 Counter & Rate Indicator User Manual

Red Lion CUB5 Counter & Rate Indicator User Manual

User Manual 12 pages · 1014 KB · EN

The CUB5 is a miniature electronic 8‑digit dual counter and rate indicator with optional relay output and serial communications modules. It operates from a 9‑28 VDC power source and offers programmable scaling, bi‑directional counting, quadrature sensing, and display color change capability.

The manual covers safety guidelines, installation steps, DIP‑switch configuration, wiring practices, optional plug‑in cards, front‑panel operation, and detailed programming procedures to customize the meter for various measurement applications.

Read online

Red CUB5 specifications

Display digit height0.48" (12.2 mm)
Input voltage range0 V to 10 V
Input current range0 mA to 20 mA or 0 mA to 50 mA
Power supply range9 VDC to 28 VDC
Enclosure ratingNEMA 4X/IP65
Weight3.2 oz (100 g)
Operating temperature range-35 °C to 75 °C
Display backlight optionsReflective or selectable red/green LED
Optional communication modulesRS232 or RS485 serial cards

Source: Red Lion CUB5P Process Meter Datasheet

All Red CUB5 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What input voltage ranges does the CUB5P support?

The meter can accept 0 V‑10 V, 0‑20 mA, or 0‑50 mA input signals, selected via a jumper and software.

From: Red Lion CUB5P Process Meter Datasheet

How is the display backlight color selected?

The LCD is available with a reflective display or a red/green LED backlight, and the backlight color can be chosen by the user.

From: Red Lion CUB5P Process Meter Datasheet

What is the input voltage range for the CUB5?

The meter operates from a power source of +9 to +28 VDC.

From: Red Lion CUB5 Counter & Rate Indicator User Manual

How can the display backlight color be changed?

The backlight version allows the user to select either green or red LED backlighting.

From: Red Lion CUB5 Counter & Rate Indicator User Manual

What input voltage does the CUB5RT require?

The meter operates from a DC supply of +9 to +28 V.

From: Red Lion CUB5RT Miniature Electronic 5‑Digit RTD Meter User Manual

Which RTD sensor types are supported?

It supports P#385, Pt392, Ni672 and Cu427 RTD sensors.

From: Red Lion CUB5RT Miniature Electronic 5‑Digit RTD Meter User Manual