Key facts
- Brand
- Metrix
- Model
- 5550
- Category
- switch
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2026-11-17
Start here

Metrix 5550 Vibralert Mechanical Vibration Switch Installation Guide and Specifications
The Metrix Model 5550 Vibralert is a mechanical vibration switch with an inertia-sensitive mechanism that activates a snap-action switch with SPDT output contacts when vibration exceeds an adjustable setpoint. The document describes use on low to medium speed machinery such as heat exchanger fans, cooling tower fans, reciprocating engines, and reciprocating compressors. The switch has a weatherproof housing with an optional hazardous-area rating and offers local reset plus an optional remote reset coil with startup delay.
Specifications and selection information cover a frequency range of 0 to 3600 RPM, setpoint adjustment from 0 to 100% of range, full-scale ranges of 5 g, 2 g, and 10 g, and contact ratings. The document also includes how-to-order tables, dimensions, wiring diagrams, typical installation diagrams, installation instructions, setpoint adjustment procedures, and electrical reset/startup lockout information.
Metrix 5550 specifications
| Function | Armature mechanism trips on high vibration and operates snap-action switch(es). |
|---|---|
| Frequency range | 0 to 3600 RPM |
| Setpoint adjustment | 0 to 100% of range; external adjustment |
| Full-scale vibration ranges | 5 g, 2 g, or 10 g |
| Reset | Local reset; optional remote reset electrical coil |
| Start delay | 20-30 seconds with reset coil voltage at startup |
| Temperature limit | -40° to +70°C (-40° to +158°F) |
| Enclosure | Cast aluminum |
| Environmental rating | NEMA 4, IP 65, and CE mark |
| Switch contact rating | 15 A at 125 or 480 Vac; 1/8 hp at 125 Vac; 1/4 hp at 250 Vac; 1/2 A at 125 Vdc; 1/4 A at 250 Vdc |
Source: Metrix 5550 Vibralert Mechanical Vibration Switch Installation Guide and Specifications
All Metrix 5550 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What happens when vibration exceeds the adjustable setpoint?
An inertia-sensitive mechanism activates a snap-action switch with SPDT output contacts.
From: Metrix 5550 Vibralert Mechanical Vibration Switch Installation Guide and Specifications
What is the frequency range of the Model 5550?
The frequency range is 0 to 3600 RPM.
From: Metrix 5550 Vibralert Mechanical Vibration Switch Installation Guide and Specifications
How is the setpoint adjusted on the Metrix 5550?
Turn the set screw on the cover clockwise to increase the setpoint and counterclockwise to decrease it; about 1/8 turn equals about 1 g.
From: Metrix 5550 and 5550G Mechanical Vibration Switch Hazardous Area Installation Manual
How long can startup lockout last?
Up to 30 seconds, or as long as voltage is continuously applied, whichever is shorter.
From: Metrix 5550 and 5550G Mechanical Vibration Switch Hazardous Area Installation Manual