Key facts
- Brand
- KYORITSU
- Model
- KEW SNAP 2002PA 2002R
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-19
Start here

Kyoritsu KEW SNAP 2002PA 2002R Digital Clamp Meter Operation Manual
This manual provides operating instructions for the KEW SNAP 2002PA and 2002R digital clamp meters, designed for measuring AC/DC current, voltage, and resistance. It includes safety warnings, measurement procedures, specifications, and details on optional accessories like the Multi-Tran M-8008 for extended current range. The device features true-RMS measurement, data hold, sleep function, and compliance with IEC 61010 safety standards.
The manual also covers battery replacement, disposal guidelines under WEEE Directive 2002/96/EC, and accessory compatibility. It is intended for safe and accurate use in electrical environments up to CAT III, with features like tear-drop jaws for tight spaces and a 4000-count display.
All Kyoritsu KEW SNAP 2002PA 2002R documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum current measurement range for the KEW SNAP 2002R?
The maximum AC current measurement range is 2000A.
From: Kyoritsu KEW SNAP 2002PA 2002R Digital Clamp Meter Operation Manual
What is the display resolution for AC voltage?
The resolution for AC voltage is 0.01V for the 40V range and 0.1V for higher ranges.
From: Kyoritsu KEW SNAP 2002PA 2002R Digital Clamp Meter Operation Manual
What is the maximum current measurement range for the KEW SNAP 2002PA?
The maximum AC current measurement range is 2000A.
From: Kyoritsu KEW SNAP 2002PA 2002R Digital Clamp Meter Instruction Manual
What is the maximum AC current measurement range for the KEW SNAP 2002PA?
The maximum AC current measurement range is 2000A.
From: Kyoritsu KEW SNAP 2002PA 2002R Digital Clamp Meter Instruction Manual