This manual introduces the features, specifications, and usage methods of KEW SNAP series KEW SNAP 2002PA 2002R digital clamp meters.
This manual provides operating instructions for the KEW SNAP 2002PA and 2002R digital clamp meters. It includes safety warnings, measurement procedures for current, voltage, and resistance, and details on features like data hold, sleep mode, and output for recorders. The manual also covers battery replacement, optional accessories, and disposal guidelines.
Specifications are detailed for both models, including measuring ranges, accuracy, and safety ratings. The device is designed to IEC 61010 safety standards and supports CAT III and CAT II measurement categories. It features tear-crop-shaped jaws, true-RMS measurement, and a 4000-count display.
| AC Current Range | 0~2000A |
|---|---|
| Resistance Range | 0~400.0kΩ |
The maximum AC current measurement range is 2000A.
The maximum AC current measurement range is 2000A.
It has a liquid crystal display with a maximum count of 4000.
It automatically powers down in about 10 minutes after the last switch operation.