Kyoritsu KEW 1012 Manuals

ManualLib has 2 documents for the Kyoritsu KEW 1012: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
KEW 1012
Documents
2
Languages
EN
Last added
2023-10-19

Start here

Kyoritsu KEW 1012 Auto Range Digital Multimeter Instruction Manual

Kyoritsu KEW 1012 Auto Range Digital Multimeter Instruction Manual

User Manual 12 pages · 457 KB · EN

This is the instruction manual for the Kyoritsu KEW 1012 digital multimeter, designed for low-voltage measurements. It includes safety warnings, operating procedures, and technical specifications. The device features auto-ranging, true RMS measurements, and multiple functions including voltage, current, resistance, and frequency. Safety precautions are emphasized, especially regarding voltage limits and proper handling of test leads.

The manual covers setup, measurement techniques, and maintenance. It specifies operating conditions, environmental limits, and overload protection. Safety symbols and measurement categories (CAT. II) are explained for user reference.

Read online

Kyoritsu KEW 1012 specifications

Measuring RangesDCV: 600.0mV to 600.0V; ACV: 600.0mV to 600.0V; DCA: 60.00mA to 10.00A; ACA: 60.00mA to 10.00A; Resistance: 600.0Ω to 60.00MΩ; Capacitance: 0.01nF to 4000μF; Frequency: 10Hz to 10MHz; Duty Cycle: 0.1% to 99.9%
AccuracyDCV: ±0.5% reading + 2 digits; ACV: ±1.5% reading + 3 digits (50/60Hz); DCA: ±1.2% reading + 3 digits; ACA: ±2.0% reading + 4 digits (40~1kHz)
Operating Temperature0°C to +40°C (relative humidity < 80%)
Storage Temperature-20°C to +60°C (relative humidity < 90%)
Overload ProtectionVoltage: 720V (RMS) for 10 seconds; Resistance: 600V (RMS) for 10 seconds; Capacitance: 600V (RMS) for 10 seconds; Frequency: 600V (RMS) for 10 seconds
Dimensions161mm (L) x 82mm (W) x 50mm (D)
Power SourceTwo R6P (AA) 1.5V batteries

Source: Kyoritsu KEW 1012 Auto Range Digital Multimeter Instruction Manual

All Kyoritsu KEW 1012 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum voltage this multimeter can measure?

The maximum voltage is 600V AC/DC, but measurements over 300V AC/DC are dangerous and not recommended.

From: Kyoritsu KEW 1012 Auto Range Digital Multimeter Instruction Manual

What is the overload protection for current measurements?

Current measurements are protected by fuses: 0.8A for mA range and 10A for A range.

From: Kyoritsu KEW 1012 Auto Range Digital Multimeter Instruction Manual

What is the maximum voltage measurement range of the KEW1012?

The maximum voltage measurement range is 600V AC or DC.

From: Kyoritsu KEW1012 Digital Multimeter Instruction Manual

What safety standards does the KEW1012 comply with?

It complies with IEC 61010-1, IEC 61010-2-033, IEC 61010-031, IEC 61326-1, and IEC 61326-2-2.

From: Kyoritsu KEW1012 Digital Multimeter Instruction Manual