KEYENCE FS-V22 Manuals

ManualLib has 2 documents for the KEYENCE FS-V22: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
KEYENCE
Model
FS-V22
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-10-07

Start here

KEYENCE FS-V22/22G/22R(P)/22X Dual Digital Fiber Sensor Instruction Manual

KEYENCE FS-V22/22G/22R(P)/22X Dual Digital Fiber Sensor Instruction Manual

User Manual 4 pages · 355 KB · EN

The document serves as an instruction manual for the KEYENCE Dual Digital Fiber Sensor models FS-V22/22G/22R(P)/22X. It covers essential topics including safety precautions, part names, amplifier expansion procedures, and connecting fiber units. The guide details various sensitivity settings such as Full Auto Calibration, Two-point Calibration, and Manual Calibration.

Read online

All KEYENCE FS-V22 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

How do I perform positioning calibration?

Press the set button for a moment without the workpiece in the sensing area; when the setting is finished the display shows the PV in green.

From: KEYENCE FS-V22R User Manual

How can I switch between light‑ON and dark‑ON output modes?

Press the mode button; the sensor toggles between light‑ON and dark‑ON modes.

From: KEYENCE FS-V22R User Manual

What is the maximum number of sub units that can be connected to each main unit?

Up to 16 sub units can be connected to each main unit.

From: KEYENCE FS-V22/22G/22R(P)/22X Dual Digital Fiber Sensor Instruction Manual

How long must the set button be pressed for Full Auto Calibration?

The set button must be pressed for a minimum of three seconds while the target workpiece is passing.

From: KEYENCE FS-V22/22G/22R(P)/22X Dual Digital Fiber Sensor Instruction Manual