Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual
This user manual covers the Hisense KFR-50LW/12FZBpJ-3 and KFR-72LW/12FZBpJ-3 air conditioners. It includes safety warnings, product components, operating instructions, maintenance and cleaning, energy-saving tips, troubleshooting, and installation guidance.
The document also provides wiring and piping diagrams, test-run procedures for cooling and heating, and technical specifications such as capacity, power input, noise levels, and fuse ratings for both models. This manual is written in Chinese.
Hisense KFR-12FZBPJ-3 specifications
| Rated power voltage | a.c 220 V |
|---|---|
| Applicable power voltage range | a.c 175 V~250 V |
| Rated cooling capacity | 5.0 kW(2.0 kW/2.45 kW/6.0 kW) for KFR-50LW/12FZBpJ-3; 7.2 kW(2.0 kW/3.6 kW/7.8 kW) for KFR-72LW/12FZBpJ-3 |
| Rated heating capacity | 6.0 kW(2.0 kW/3.0 kW/9.8 kW) for KFR-50LW/12FZBpJ-3; 8.6 kW(2.0 kW/4.3 kW/10.6 kW) for KFR-72LW/12FZBpJ-3 |
| Indoor noise level | 34 dB(A) // 44 dB(A) for KFR-50LW/12FZBpJ-3; 35 dB(A) // 45 dB(A) for KFR-72LW/12FZBpJ-3 |
| Outdoor noise level | 47 dB(A) // 55 dB(A) for KFR-50LW/12FZBpJ-3; 48 dB(A) // 57 dB(A) for KFR-72LW/12FZBpJ-3 |
| Net weight | 39.5kg // 35.5kg for KFR-50LW/12FZBpJ-3; 39.5 kg // 53.0 kg for KFR-72LW/12FZBpJ-3 |
Source: Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual
All Hisense KFR-12FZBPJ-3 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How long should the test run last after installation?
The test run after installation should last more than half an hour.
From: Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual
How long must you wait before restarting the air conditioner after it stops?
You must wait 3 minutes for the compressor to restart.
From: Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual
Who may wire the product?
Only qualified electricians may wire the product, and all wiring must follow relevant electrical regulations.
What should be done before installation, wiring, piping, and inspection are finished?
Make sure the power is disconnected before completing all installation, wiring, piping, and inspection.