Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual

Hisense air conditioner user manual, introduces the composition, operation method, maintenance and cleaning of the air conditioner.


Hisense air conditioner KFR-50LW/12FZBpJ-3 KFR-72LW/12FZBpJ-3makeuse installation Manual - cover page
Brand
Hisense
Category
Air conditioner
Document type
User Manual
Language
Chinese
Pages
30
File format
PDF
File size
12.9 MB
Published
15 March, 2012
Updated
30 September, 2023
MD5 checksum
301FD6AAE601FDB7BC9FE62DE36AF8C8

About this manual

This user manual covers the Hisense KFR-50LW/12FZBpJ-3 and KFR-72LW/12FZBpJ-3 air conditioners. It includes safety warnings, product components, operating instructions, maintenance and cleaning, energy-saving tips, troubleshooting, and installation guidance.

The document also provides wiring and piping diagrams, test-run procedures for cooling and heating, and technical specifications such as capacity, power input, noise levels, and fuse ratings for both models. This manual is written in Chinese.

What's inside

  • Warning signs
  • Precautions
  • Air conditioner components
  • Operation guide
  • Maintenance and cleaning
  • Energy-saving suggestions
  • Troubleshooting
  • Refrigerant cycle diagram
  • Installation manual
  • Technical specifications

Specifications

Rated power voltagea.c 220 V
Applicable power voltage rangea.c 175 V~250 V
Rated cooling capacity5.0 kW(2.0 kW/2.45 kW/6.0 kW) for KFR-50LW/12FZBpJ-3; 7.2 kW(2.0 kW/3.6 kW/7.8 kW) for KFR-72LW/12FZBpJ-3
Rated heating capacity6.0 kW(2.0 kW/3.0 kW/9.8 kW) for KFR-50LW/12FZBpJ-3; 8.6 kW(2.0 kW/4.3 kW/10.6 kW) for KFR-72LW/12FZBpJ-3
Indoor noise level34 dB(A) // 44 dB(A) for KFR-50LW/12FZBpJ-3; 35 dB(A) // 45 dB(A) for KFR-72LW/12FZBpJ-3
Outdoor noise level47 dB(A) // 55 dB(A) for KFR-50LW/12FZBpJ-3; 48 dB(A) // 57 dB(A) for KFR-72LW/12FZBpJ-3
Net weight39.5kg // 35.5kg for KFR-50LW/12FZBpJ-3; 39.5 kg // 53.0 kg for KFR-72LW/12FZBpJ-3

Frequently asked questions

How long should the test run last after installation?

The test run after installation should last more than half an hour.

How long must you wait before restarting the air conditioner after it stops?

You must wait 3 minutes for the compressor to restart.

What is the reliable operating temperature range for the heat pump air conditioner?

It can reliably operate in T1 conditions with a heat pump temperature range of -7℃ to 43℃.

Download PDF (12.9 MB)

More Hisense Manuals