Key facts
- Brand
- Endevco
- Model
- 6634C
- Category
- Industrial Robot
- Documents
- 4
- Languages
- EN
- Last added
- 2023-10-18
Start here

IM6634C Vibration Amplifier Instruction Manual
This manual provides detailed instructions for operating the Endevco Model 6634C Vibration Amplifier, a microprocessor-based signal conditioning instrument for vibration testing. It covers unpacking, jumper configuration, input/output settings, alarm functions, and RS-232 interface commands. Maintenance procedures and theory of operation are also included.
The 6634C supports various input types including piezoelectric accelerometers and external calibration sources, with outputs configurable for acceleration, velocity, or displacement. It can be expanded with optional boards like the Model 35840A filter or Model 35843 serial interface.
Endevco 6634C specifications
| Input Sources | External Calibration Source, Single Ended Piezoelectric (PE) Accelerometer, Differential PE Accelerometer |
|---|---|
| Output Signals | Broadband acceleration, Acceleration (50 mV/g pk), Velocity (100 mV/ips pk), Displacement (200 mV/mil pk-pk) |
| Power Supply | 45 to 440 Hz AC, 90 - 240 VAC |
| Alarm Outputs | Two TTL compatible latched alarm outputs |
| Output Voltage Settings | AC Output: 1V, 5V, or 10V pk; DC Output: 1V, 5V, or 10V |
All Endevco 6634C documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What input types does the 6634C support?
It supports External Calibration Source, Single Ended Piezoelectric (PE) Accelerometer, and Differential PE Accelerometer.
What is the power supply requirement?
It operates on 45 to 440 Hz AC, 90 - 240 VAC, with an internal switch for voltage selection.
What types of input sources does the 6634C support?
The 6634C supports External Calibration Source, Single Ended Piezoelectric (PE) Accelerometer, and Differential PE Accelerometer.
What output signals can the 6634C produce?
It produces Broadband acceleration, Acceleration (50 mV/g pk), Velocity (100 mV/ips pk), and Displacement (200 mV/mil pk-pk).
What input sources does the Model 6634C accept?
The instrument accepts inputs from an External Calibration Source, Single-ended piezoelectric accelerometer, Differential PE accelerometer, and Velocity Coil transducer.
Can the full-scale output amplitude be adjusted?
Yes, the DC and AC Full Scale Outputs can be independently set to 1V, 5V, or 10V using internal jumpers.
