Installation instructions, safety guidelines, and technical specifications for the Tracopower TCL Series Industrial Power Supply.
This document provides installation instructions and technical specifications for the Tracopower TCL Series Industrial Power Supply. It details input voltage ranges, output power ratings, output voltage adjustment methods, and recommended circuit breaker characteristics for various models within the series.
| Input Voltage Range | 85VAC – 264VAC |
|---|---|
| Operating Temperature Range | -10°C – +70°C |
| Storage Temperature Range | -25°C – +85°C |
| Output Power Derating | 1.5%/K above +40°C |
| Parallel Operation | Up to 5 power supplies |
The recommended tightening torque is 0.5 to 0.7Nm (4.5 to 6.2lb.in.).
No, the power supply must be operated only if the PE terminal is connected to the non-fused earth conductor to comply with EMC and safety standards.