Texas Instruments TPS40007-Based Converter User's Guide

Texas Instruments TPS40007-based converter user's guide for the 10-A output evaluation module, including features, design procedure, and safety warnings.


Texas Instruments TPS40007-Based Converter User's Guide - cover page
Brand
Texas Instruments
Category
DC/DC Converter
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
306 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5D23FCDDF7E38E0DD3EAC4144EFF958E

About this manual

This user's guide describes the Texas Instruments TPS40007-based converter evaluation module, which delivers a 10-A output. The kit is intended for engineering development or evaluation purposes only and is not considered fit for commercial use.

It covers the TPS40007 synchronous buck PWM controller, a 3 V to 5 V input converted to a 2.5-V output, and includes features, schematic, design procedure, test results, PCB layout, and list of material. Safety warnings address the input voltage range, component temperatures above 50 °C, and proper handling precautions.

What's inside

  • Introduction
  • Features
  • Schematic
  • Design Procedure
  • PowerPAD Packaging
  • Test Results/Performance Data
  • PCB Layout
  • List of Material
  • Dynamic Warnings and Restrictions
  • Important Notice

Specifications

Input voltage3.3 V to 5 V
Output voltage2.5 V +/−3%
Output current0 A to 10 A
Efficiency> 95% with V IN = 3.3 V
Output voltage ripple< 2% V OUT
Switching frequency300 kHz

Frequently asked questions

What is the input voltage range for the EVM?

The EVM must be operated within an input voltage range of 0 V DC to 5.5 V DC.

What output current does the converter provide?

The converter provides an output current from 0 A to 10 A.

Is the evaluation kit intended for commercial use?

No, the kit is intended for engineering development or evaluation purposes only and is not considered fit for commercial use.

How hot can circuit components get during normal operation?

Some circuit components may have case temperatures greater than 50 °C during normal operation.

Download PDF (306 KB)

More Texas Instruments Manuals