Texas Instruments TIDA-01630 High EMC Immunity RS485 Interface Reference Design

This document describes the Texas Instruments TIDA-01630 reference design for high EMC immunity RS485 interfaces with Tamagawa encoders.


Texas Instruments TIDA-01630 High EMC Immunity RS485 Interface Reference Design - cover page
Brand
Texas Instruments
Category
Industrial Robot
Document type
Product Leaflet
Language
Chinese
Pages
30
File format
PDF
File size
2.7 MB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
1F8CE057A3A53823376A8E1E52081E13

About this manual

The TIDA-01630 is a reference design implementing a high EMC immunity RS485 digital interface for absolute position encoders, specifically using the Tamagawa T-Format protocol. It is designed to support industrial servo drives and robotics applications where robust communication is critical against harsh electrical environments. This manual is written in Chinese.

What's inside

  • System Description
  • IEC61800-3 EMC Immunity Standard
  • TIDesign Overview
  • Key System Specifications
  • System Overview
  • Block Diagram
  • Design Considerations
  • Digital Interface
  • Power Supply
  • Resources

Specifications

DC input voltage5V
RS485 interface1 channel halfduplex
RS485 transfer rate50MBaud
Temperature range-40 to 85°C
Cable length supportup to 50 m
I/O interface signaling voltage3.3V

Frequently asked questions

What encoder protocol does this design support?

This design supports the Tamagawa T-format serial interface.

What is the maximum cable length supported?

The design supports cable lengths of up to at least 50m.

Which EMC standard is this design tested against?

The design has been tested against IEC61000-4-4.