Texas Instruments TIDA-01630 reference design for a high-EMC-immunity RS485 interface for Tamagawa encoders in industrial drives.
Texas Instruments TIDA-01630 is a reference design for a high-EMC-immunity RS485 digital interface for absolute position encoders, including Tamagawa T-Format. It combines a bidirectional 2-wire RS485 interface, an encoder power supply protected by a load switch, and a 3.3 V digital interface to a host processor.
The design supports two-wire standards such as Tamagawa and four-wire RS485 standards such as EnDat 2.2 and BiSS. It is intended for applications such as servo CNC and robotics, AC inverters and VF drives, position sensors (encoders), and industrial robots. This manual is written in Japanese.
| Input voltage | 5 V to 15 V |
|---|---|
| Logic I/O voltage | 3.3 V |
| Encoder supply voltage | Equal to Vin |
| Tested cable length | Up to 50 m |
| RS485 transceiver | THVD1550; 5 V half-duplex; up to 50 Mbps |
| ESD and EFT immunity | 16 kV IEC ESD and 4 kV EFT |
| EMC standard | IEC 61000-4-4 |
| Drive EMC immunity | IEC 61800-3 |
| Supported interfaces | Tamagawa (2-wire); EnDat 2.2 and BiSS (4-wire RS485) |
| Form factor | BoosterPack plug-in module compatible with LaunchPad development kit |
It supports two-wire standards such as Tamagawa and four-wire RS485 standards such as EnDat 2.2 and BiSS.
The design was tested with cable lengths up to 50 m.
The design uses 16 kV IEC ESD and 4 kV EFT.
It provides a 3.3 V digital interface to the host processor.