Texas Instruments TIDA-01630 High EMC Immunity RS485 Interface Reference Design

Texas Instruments TIDA-01630 reference design for a high-EMC-immunity RS485 interface for Tamagawa encoders in industrial drives.


Texas Instruments TIDA-01630 High EMC Immunity RS485 Interface Reference Design - cover page
Brand
Texas Instruments
Category
Other Electronics
Document type
Application Note
Language
Japanese
Pages
30
File format
PDF
File size
2.7 MB
Published
20 November, 2026
Updated
20 November, 2026
MD5 checksum
5FF746018FCBA1F66E689C4CD7F5989D

About this manual

Texas Instruments TIDA-01630 is a reference design for a high-EMC-immunity RS485 digital interface for absolute position encoders, including Tamagawa T-Format. It combines a bidirectional 2-wire RS485 interface, an encoder power supply protected by a load switch, and a 3.3 V digital interface to a host processor.

The design supports two-wire standards such as Tamagawa and four-wire RS485 standards such as EnDat 2.2 and BiSS. It is intended for applications such as servo CNC and robotics, AC inverters and VF drives, position sensors (encoders), and industrial robots. This manual is written in Japanese.

What's inside

  • System Description
  • IEC 61800-3 EMC Immunity Standard
  • TIDesign Overview
  • Absolute Position Encoder Digital Interface TIDesigns
  • Features
  • Applications
  • Resources

Specifications

Input voltage5 V to 15 V
Logic I/O voltage3.3 V
Encoder supply voltageEqual to Vin
Tested cable lengthUp to 50 m
RS485 transceiverTHVD1550; 5 V half-duplex; up to 50 Mbps
ESD and EFT immunity16 kV IEC ESD and 4 kV EFT
EMC standardIEC 61000-4-4
Drive EMC immunityIEC 61800-3
Supported interfacesTamagawa (2-wire); EnDat 2.2 and BiSS (4-wire RS485)
Form factorBoosterPack plug-in module compatible with LaunchPad development kit

Frequently asked questions

What encoder interfaces does the TIDA-01630 support?

It supports two-wire standards such as Tamagawa and four-wire RS485 standards such as EnDat 2.2 and BiSS.

What cable length was the design tested with?

The design was tested with cable lengths up to 50 m.

What EMC immunity levels are mentioned for the transceiver?

The design uses 16 kV IEC ESD and 4 kV EFT.

What host interface voltage does the design provide?

It provides a 3.3 V digital interface to the host processor.